SN-CEN/TR 16243:2011 PDF

SN-CEN/TR 16243:2011 PDF

Name:
SN-CEN/TR 16243:2011 PDF

Published Date:
08/17/2011

Status:
Active

Description:

Ambient air quality — Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters

Publisher:
Standards Norway SN-CEN/TR Series

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
Need Help?
ADOPTED_FROM:CEN/TR 16243:2011 This Technical Report gives guidance on the measurement of elemental carbon (EC) and organic carbon (OC) following the requirement for the networks of all EU member countries to measure EC and OC in particulate matter from June 2010 at background sites according to the Council Directive 2008/50/EC on ambient air quality and cleaner air for Europe. The Technical Report describes the analytical procedures for determining EC and OC on quartz fibre filters as μg/cm2, and the subsequent calculation of concentrations as µg/m³. Sampling onto filters is to be done in accordance with EN 14907 for PM2,5. The sampling process determines the size fraction of the particulate matter, the retention of semi-volatile material, and ab/desorption of volatile organic compounds on the filter at the time of sampling. The same analysis method may also be used for other size fractions. Any possible additional artefacts e.g. due to charring or higher concentrations of carbonates would need to be assessed in those cases. The measurement procedures are applicable for: - rural background, - urban background, - road side and - industrial sites. The scope includes non rural site measurements, to allow the assessment of additional exposure of people in urban areas as stated in the objectives of the council directive and to achieve coherence in the European approach. Measurements are made over a nominal sampling period of 24 h, and concentrations are expressed as μg/m³, where the volume of air is the volume at ambient conditions near the inlet of the sampler at the time of sampling. The applicable concentration range of the proposed method is limited by the optical correction, instrument, and thermal protocols applied in the analysis of EC and OC. Therefore no definitive values can be given. The experience from EMEP shows the applicability of the method at regional background sites.
Number of Pages : 32
Published : 08/17/2011

History


Related products


Best-Selling Products

NR 5002881/R/71310/001 ISSUE 4
Published Date: 04/01/2004
Standard Brickwork & Masonry Repair Details - Approval in Principle
$24.3
NR 656JRM02 ISSUE 1.2
Published Date: 09/13/2000
PC-BASED ISM TERMINAL HARDWARE SPECIFICATION
$7.5
NR 656JRM03 ISSUE 1.1
Published Date: 09/11/2000
PC Based ISM Terminal Installation & Maintenance Manual
$13.2
NR 684021-BTA-00-101 ISSUE 3
Published Date: 12/01/2008
Form A & B: Traditional Front Wall Platform
$35.4
NR 684021-BTA-00-102 ISSUE 1
Published Date: 12/17/2008
Form A & B: Crosswall & Precast Planks
$35.4
NR 84-YS-1003/30 ISSUE H
Published Date: 04/02/2005
CCTV Monitored L.C. - Standard S.B. Control Unit Construction Details Index
$5.7